Datasheet - A p p l i c a t i o n I n f o r m a t i o n
9 Application Information
Error Detection
The AS1113 features two types of error detection. The error detection can be used on-the-fly, for active LEDs, without
any delay, or by entering into low-current diagnosis mode.
Error Detection On-The-Fly
Error detection on-the-fly will output the status of active LEDs during operation. Without choosing an error mode this
will output the temperature flag at every input/output cycle. Triggering one clock pulse for open or two clock pulses for
short detection during error detection mode outputs the detailed open- or short-error report with the next input/output
cycle (see Figure 18) . LEDs turned off at test time are not tested and will show a logic "1" at the detailed error report.
Figure 18. Normal Operation with Error Detection During Operation – 64 Cascaded AS1113s
Display
SDI
Data1
Data2
Data2
Data3
Data3
Data4
SDO
T/O or S Error Code
Data0
GEF
T/O or S Error Code
Data1
GEF
T/O or S Error Code
Data2
Clock for Error
Clock for Error
CLK
1024x
Mode 0x/1x/2x
1024x
Mode 0x/1x/2x
1024x
OEN
Rising Edge of OEN
Acquisition of Error Status
Rising Edge of OEN
Acquisition of Error Status
LD
Current
Falling Edge of LD; Error Register is
copied into Shift Register
≤ 50mA
Falling Edge of LD; Error Register is
copied into Shift Register
GEF = Global Error Flag
Error Detection with Low-Current Diagnosis Mode
This unique feature of the AS1113 uses an internal all 1s test pattern for a flicker free diagnosis of all LEDs. This error
detection mode can be started at the end of each input cycle (see Figure 19) .
Figure 19. Low-Current Diagnosis Mode with Internal All 1s Test Pattern – 64 Cascaded AS1113s
Low-Current Diagnosis Mode
Display
SDI
Data0
Data1
Data1
Data2
Data2
Data3
SDO
T/O or S Error Code
Data0
GEF
O or S Error Code from
All 1s Test Pattern
GEF
Temperature Error Code
3x Clocks Low- Clock for Error
Current Mode
Mode 1x/2x
CLK
1024x
1024x
1024x
Test Pattern
OEN
LD
Rising Edge of OEN
Acquisition of Error Status
Use Internal All 1s Falling Edge of LD; Error Register
is copied into Shift Register
Current
≤ 50mA
≤ 0.8mA
≤ 50mA
GEF = Global Error Flag
www.austriamicrosystems.com/LED-Driver-ICs/AS1113
Revision 1.04
17 - 24
相关PDF资料
AS1117-BQFT IC DRIVER 64LED MOBILE 24-TQFN
AS1118-BQFT IC DRIVER 64LED W/DELAY 24-TQFN
AS1121B-BQFT IC DRIVER 16-CH 32-TQFN
AS1122B-BQFT IC LED DVR 12-CH 24-TQFN
AS1123-BTST IC LED DVR 16-CH 40MA 24-QSOP
AS1390A-ZQFT IC BOOST CTLR/BUCK CONV 20-QFN
AS212-L SOCKET 12V AUTO SAFETY CAP MNT
AS212C AUTO 12V SOCKET W/SAFETY CAP
相关代理商/技术参数
AS1113BSSU 制造商:AMS 功能描述:IC LED DRIVER CONSTANT CURRENT SSOP24 制造商:AMS 功能描述:IC, LED DRIVER, CONSTANT CURRENT, SSOP24 制造商:AMS 功能描述:IC, LED DRIVER, CONSTANT CURRENT, SSOP24; Topology:Constant Current; No. of Outputs:16; Output Current:50mA; Output Voltage:15V; Driver Case Style:SSOP; Input Voltage Min:3V; Input Voltage Max:5.5V; Dimming Control Type:Analogue ;RoHS Compliant: Yes
AS1113-BSSU 功能描述:LED显示驱动器 RoHS:否 制造商:Micrel 数位数量:5 片段数量: 安装风格:SMD/SMT 封装 / 箱体:PLCC-44 工作电源电压:4.75 V to 11 V 最大电源电流:10 mA 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装:Tube
AS1113CVB 功能描述:AS1113 - Power Management, Power Over Ethernet (POE) Evaluation Board 制造商:akros silicon 系列:- 零件状态:停产 主要用途:电源管理,以太网供电(POE) 嵌入式:- 使用的 IC/零件:AS1113 主要属性:- 辅助属性:过压,热和欠压保护 所含物品:板 标准包装:1
AS1113-XXX-I-A1-D 制造商:未知厂家 制造商全称:未知厂家 功能描述:Analog Filter
AS1113-XXX-I-A1-S 制造商:未知厂家 制造商全称:未知厂家 功能描述:Analog Filter
AS1113-XXX-I-A2-D 制造商:未知厂家 制造商全称:未知厂家 功能描述:Analog Filter
AS1113-XXX-I-A2-S 制造商:未知厂家 制造商全称:未知厂家 功能描述:Analog Filter
AS1113-XXX-I-A3-D 制造商:未知厂家 制造商全称:未知厂家 功能描述:Analog Filter